44 lines
1.9 KiB
C
44 lines
1.9 KiB
C
/**
|
|
**************************************************************************
|
|
* @file interface_config.h
|
|
* @brief Конфигурация для модбаса
|
|
*************************************************************************/
|
|
#ifndef _MODBUS_CONFIG_H_
|
|
#define _MODBUS_CONFIG_H_
|
|
#include "stm32f1xx_hal.h"
|
|
|
|
// MODBUS PARAMS
|
|
#define MODBUS_DEVICE_ID 1 ///< девайс текущего устройства
|
|
#define MODBUS_TIMEOUT 5000 ///< максимальнйы тайтаут MB в тиках таймера
|
|
|
|
// STRING OBJECTS MODBUS
|
|
#define MODBUS_VENDOR_NAME "NIO-12"
|
|
#define MODBUS_PRODUCT_CODE ""
|
|
#define MODBUS_REVISION "Ver. 1.0"
|
|
#define MODBUS_VENDOR_URL ""
|
|
#define MODBUS_PRODUCT_NAME ""
|
|
#define MODBUS_MODEL_NAME "STM32F103"
|
|
#define MODBUS_USER_APPLICATION_NAME ""
|
|
|
|
// PERIPH FUNCTIONS AND HANDLERS
|
|
#define RS_UART_Init MX_USART1_UART_Init
|
|
#define RS_UART_DeInit HAL_UART_MspDeInit
|
|
#define RS_TIM_Init MX_TIM3_Init
|
|
#define RS_TIM_DeInit HAL_TIM_Base_MspDeInit
|
|
#define rs_huart huart1
|
|
#define rs_htim htim3
|
|
|
|
|
|
/**
|
|
* @brief Поменять комманды 0x03 и 0x04 местами (для LabView терминалки от двигателей)
|
|
* @details Терминалка от двигателей использует для чтения регистров комманду R_HOLD_REGS вместо R_IN_REGS
|
|
* Поэтому чтобы считывать Input Regs - надо поменять их местами.
|
|
*/
|
|
//#define MODBUS_SWITCH_COMMAND_R_IN_REGS_AND_R_HOLD_REGS
|
|
|
|
/////////////////////////////////////////////////////////////////////
|
|
/////////////////////////---CALC DEFINES---//////////////////////////
|
|
|
|
|
|
|
|
#endif //_MODBUS_CONFIG_H_
|